ECO TechFlexibility and immediacy

Easy set-up and simple commissioning. This drive is designed to control and pilot a wide range of brushless and asynchronous motors.
  • Feedback: Incremental Encoder, BiSS absolute encoder, resolver, Hiperface DSL
  • Fieldbus: CAN Open DS402, EtherCAT or ModBUS RTU
  • 12 digital Inputs / 4 digital output
  • 2 analog input +/- 10V differential
  • Protection Level: IP20
  • Standards: CE
  • Safety Torque Off circuit
  • High overload capability
  • Control of brushless motors from 0.7 to 1000 Nm and asynchronous motors.
  • Available from 4 to 60 A nominal current, with voltage supply from 230 to 400 Vac.
  • Easy set-up and simple commissioning are guaranteed by a special one-digit firmware.

9XECO2T0410.. - 9XECO2T0615..


9XECO2T0410..
9XECO2T0615..
Supply Voltage Power Stage (Vac)
1/3 x 230
Supply Frequency (Hz)
50/60
Voltage Supply Control Stage (Vac)
24
Output Power (kW)
1,0
1,7
Continuous Output Current (ARMS)
4
6
Peak Output Current (for 2 s) (ARMS)
10
15
Output Frequency (Hz)
Up to 300
Switching Frequency PWM (kHz)
8
Analogue Input
1 x +/- 10 V and 1 x 0 - 10 V
Analogue Output
No
Digital Input
12 x +24 Vdc (programmable)
Digital Output
5 x +24 Vdc 0,5 A (Drive OK + programmable)
Status Led
No
Keypad
Yes
Encoder Input
TTL Incremental 5V LD (2048 - 5000 - 4096 ppr) or BiSS absolute (with option board) or Hyperface DSL or Sin/Cos or Resolver
Encoder Output
Yes
FieldBUS
CANopen DS402 - Mod BUS IP - S-NET - S-CAN - EtherCAT - Ethernet IP - Profinet 10
Functions
Analog Input - Pulse - Electronic Gearbox - Electronic CAM - Stand Alone Positioner - MSQ - FieldBus Drive
Protection
12T, thermal, overvoltage, undervoltage, short-circuit
Connection Type
Connectors
Brake management
On integrated brake resistor or external brake resistor
Motor types
AC Brushless sinusoidal, Asynchronous AC
Configuration drive
With Drivewatcher Software or keypad on board
Power Loss (W)
19 @ I nominal
26 @ 1 nominal
Operating Temperature (°C)
0 ... + 40 (de-rate by 50% up to 55°C)
Storage Temperature (°C)
-25 ... + 85
Humidity
5% .. 95% (not condensing)
Altitude
Up to 1000 m above sea level without derating
Weight (kg)
1,3
1,5
Protection degree
IP 20
Certifications
2014/35/UE - 2014/30/UE - 2011/65/EU CEI EN 61800-3 2005 - CEI EN 61800-2 - El EN 61800-5-1 2009
UL Certification
NO

9XECO4T0410.. - 9XECO4T0512..


9XECO4T0410..
9XECO4T0512..
Supply Voltage Power Stage (Vac)
3 x 400
Supply Frequency (Hz)
50/60
Voltage Supply Control Stage (Vac)
24
Output Power (kW)
2,2
2,7
Continuous Output Current (ARMS)
4
5
Peak Output Current (for 2 s) (ARMS)
10
12
Output Frequency (Hz)
Up to 300
Switching Frequency PWM (kHz)
8
Analogue Input
1 x +/- 10 V and 1 x 0 - 10 V
Analogue Output
No
Digital Input
12 x +24 Vdc (programmable)
Digital Output
5 x +24 Vdc 0,5 A (Drive OK + programmable)
Status Led
No
Keypad
Yes
Encoder Input
TTL Incremental 5V LD (2048 - 5000 - 4096 ppr) or BiSS absolute (with option board) or Hyperface DSL or Sin/Cos or Resolver
Encoder Output
Yes
FieldBUS
CANopen DS402 - Mod BUS IP - S-NET - S-CAN - EtherCAT - Ethernet IP - Profinet 10
Functions
Analog Input - Pulse - Electronic Gearbox - Electronic CAM - Stand Alone Positioner - MSQ - FieldBus Drive
Protection
12T, thermal, overvoltage, undervoltage, short-circuit
Connection Type
Connectors
Brake management
On integrated brake resistor or external brake resistor
Motor types
AC Brushless sinusoidal, Asynchronous AC
Configuration drive
With Drivewatcher Software or keypad on board
Power Loss (W)
25 @ I nominal
31 @ I nominal
Operating Temperature (°C)
0 ... + 40 (de-rate by 50% up to 55°C)
Storage Temperature (°C)
-25 ... + 85
Humidity
5% .. 95% (not condensing)
Altitude
Up to 1000 m above sea level without derating
Weight (kg)
2,2
2,5
Protection degree
IP 20
Certifications
2014/35/UE - 2014/30/UE - 2011/65/EU CEI EN 61800-3 2005 - CEI EN 61800-2 - El EN 61800-5-1 2009
UL Certification
NO

9XECO4T1020.. - 9XECO4T2040..


9XECO4T1020..
9XECO4T2040..
Supply Voltage Power Stage (Vac)
3 x 400
Supply Frequency (Hz)
50/60
Voltage Supply Control Stage (Vac)
24
Output Power (kW)
4,5
9,0
Continuous Output Current (ARMS)
10
20
Peak Output Current (for 2 s) (ARMS)
20
40
Output Frequency (Hz)
Up to 300
Switching Frequency PWM (kHz)
8
Analogue Input
1 x +/- 10 V and 1 x 0 - 10 V
Analogue Output
No
Digital Input
12 x +24 Vdc (programmable)
Digital Output
5 x +24 Vdc 0,5 A (Drive OK + programmable)
Status Led
No
Keypad
Yes
Encoder Input
TTL Incremental 5V LD (2048 - 5000 - 4096 ppr) or BiSS absolute (with option board) or Hyperface DSL or Sin/Cos or Resolver
Encoder Output
Yes
FieldBUS
CANopen DS402 - Mod BUS IP - S-NET - S-CAN - EtherCAT - Ethernet IP - Profinet 10
Functions
Analog Input - Pulse - Electronic Gearbox - Electronic CAM - Stand Alone Positioner - MSQ - FieldBus Drive
Protection
12T, thermal, overvoltage, undervoltage, short-circuit
Connection Type
Connectors
Brake management
On integrated brake resistor or external brake resistor
Motor types
AC Brushless sinusoidal, Asynchronous AC
Configuration drive
With Drivewatcher Software or keypad on board
Power Loss (W)
56 @ I nominal
103 @ I nominal
Operating Temperature (°C)
0 ... + 40 (de-rate by 50% up to 55°C)
Storage Temperature (°C)
-25 ... + 85
Humidity
5% .. 95% (not condensing)
Altitude
Up to 1000 m above sea level without derating
Weight (kg)
4,2
7,5
Protection degree
IP 20
Certifications
2014/35/UE - 2014/30/UE - 2011/65/EU CEI EN 61800-3 2005 - CEI EN 61800-2 - El EN 61800-5-1 2009
UL Certification
NO

9XECO4T2550.. - 9XECO4T3090..


9XECO4T2550..
9XECO4T3090..
Supply Voltage Power Stage (Vac)
3 x 400
Supply Frequency (Hz)
50/60
Voltage Supply Control Stage (Vac)
24
Output Power (kW)
11,2
13,5
Continuous Output Current (ARMS)
25
30
Peak Output Current (for 2 s) (ARMS)
50
90
Output Frequency (Hz)
Up to 300
Switching Frequency PWM (kHz)
8
Analogue Input
1 x +/- 10 V and 1 x 0 - 10 V
Analogue Output
No
Digital Input
12 x +24 Vdc (programmable)
Digital Output
5 x +24 Vdc 0,5 A (Drive OK + programmable)
Status Led
No
Keypad
Yes
Encoder Input
TTL Incremental 5V LD (2048 - 5000 - 4096 ppr) or BiSS absolute (with option board) or Hyperface DSL or Sin/Cos or Resolver
Encoder Output
Yes
FieldBUS
CANopen DS402 - Mod BUS IP - S-NET - S-CAN - EtherCAT - Ethernet IP - Profinet 10
Functions
Analog Input - Pulse - Electronic Gearbox - Electronic CAM - Stand Alone Positioner - MSQ - FieldBus Drive
Protection
12T, thermal, overvoltage, undervoltage, short-circuit
Connection Type
Connectors
Brake management
On integrated brake resistor or external brake resistor
Motor types
AC Brushless sinusoidal, Asynchronous AC
Configuration drive
With Drivewatcher Software or keypad on board
Power Loss (W)
140 @ I nominal
190 @ I nominal
Operating Temperature (°C)
0 ... + 40 (de-rate by 50% up to 55°C)
Storage Temperature (°C)
-25 ... + 85
Humidity
5% .. 95% (not condensing)
Altitude
Up to 1000 m above sea level without derating
Weight (kg)
8,5
9,7
Protection degree
IP 20
Certifications
2014/35/UE - 2014/30/UE - 2011/65/EU CEI EN 61800-3 2005 - CEI EN 61800-2 - El EN 61800-5-1 2009
UL Certification
NO

9XECO4T40120.. - 9XECO4T60180..


9XECO4T40120..
9XECO4T60180..
Supply Voltage Power Stage (Vac)
3 x 400
Supply Frequency (Hz)
50/60
Voltage Supply Control Stage (Vac)
24
Output Power (kW)
18,0
27,0
Continuous Output Current (ARMS)
40
60
Peak Output Current (for 2 s) (ARMS)
120
180
Output Frequency (Hz)
Up to 300
Switching Frequency PWM (kHz)
8
Analogue Input
1 x +/- 10 V and 1 x 0 - 10 V
Analogue Output
No
Digital Input
12 x +24 Vdc (programmable)
Digital Output
5 x +24 Vdc 0,5 A (Drive OK + programmable)
Status Led
No
Keypad
Yes
Encoder Input
TTL Incremental 5V LD (2048 - 5000 - 4096 ppr) or BiSS absolute (with option board) or Hyperface DSL or Sin/Cos or Resolver
Encoder Output
Yes
FieldBUS
CANopen DS402 - Mod BUS IP - S-NET - S-CAN - EtherCAT - Ethernet IP - Profinet 10
Functions
Analog Input - Pulse - Electronic Gearbox - Electronic CAM - Stand Alone Positioner - MSQ - FieldBus Drive
Protection
12T, thermal, overvoltage, undervoltage, short-circuit
Connection Type
Connectors
Brake management
On integrated brake resistor or external brake resistor
Motor types
AC Brushless sinusoidal, Asynchronous AC
Configuration drive
With Drivewatcher Software or keypad on board
Power Loss (W)
220 @ I nominal
280 @ I nominal
Operating Temperature (°C)
0 ... + 40 (de-rate by 50% up to 55°C)
Storage Temperature (°C)
-25 ... + 85
Humidity
5% .. 95% (not condensing)
Altitude
Up to 1000 m above sea level without derating
Weight (kg)
23
23
Protection degree
IP 20
Certifications
2014/35/UE - 2014/30/UE - 2011/65/EU CEI EN 61800-3 2005 - CEI EN 61800-2 - El EN 61800-5-1 2009
UL Certification
NO

Related Products