- Graphic Display 256×96 pixels, with white LED backlighting.
- Intuitive menus with resistive touch screen interface.
- Data transmission to the Data Manager through RS485 ModBus or Radio Sub1Ghz (868MHz).
- Possibility to connect up to 250 devices to a single EW900 Data Manager.
- Single or three-phase energy meter.
- Measurement of active, reactive and apparent energy
- Measurement of active, reactive and apparent power
- Electrical parameters measured: current, voltage, active, reactive and apparent power, power factor
- Line quality: harmonics (1st…51th), THD.
- Precision: class active energy.
- Data refresh on display: 1 second.
EW800Distributed multifunction meter
Our distributed meter is designed to accurately measure energy consumption of systems and machines. Based on the IoT, it collects data in real time and automatically send them to the Data Manager for analysis. Hence, it promotes energy efficiency and digitalization in the plant.
EW800A
DEM (Distributed Embedded Meter) with internal shunts for current measurements up to 64A, equipped with integrated touch LCD display available with
- integrated I/O module with 2 digital inputs and 2 digital outputs
- serial communication interface RS485
- radio communication interface RF868 MHZ
EW800A DEM | |
---|---|
Connections | Single-phase Three-phase 4 wires with Y load Three-phase 4 wires with D load |
Measuring inputs - Current Channels | Direct up to 64A (45kW) three-phase connection, up to 21A (15kW) single-phase connection |
Measuring inputs - Voltage Channels | Direct (max rated voltage phase-neutral 230Vac) |
Power supply | self-powered |
Communication | RS485 ModBus (in all EW800… models) Radio RF868 MHz (only in EW800…200 models) Ethernet (only in EW800…300 models) |
Digital Isolated Input/Output | 2 I/O module option (configurable by Data Manager) THD |
Measures | Voltage (phase-neutral and phase-phase) Current (phase values and neutral value) Imported Active Energy (phase values and total value) Exported Active Energy (phase values and total value) Imported Active Power (phase values and total value) Exported Active Power (phase values and total value) Reactive Power with sign (phase values and total value) Apparent Power (phase values and total value) Power Factor (phase values and total value) Frequency |
Harmonic analysis | THD (in voltage / current signal) Harmonics 1st ...51st (in voltage / current signal) |
Accuracy - Active Energy (according to IED 62053-21) | Class 1 |
Accuracy - Reactive Energy (according to IED 62053-23) | Class 2 |
Accuracy - Current and Voltage | ≤ 0,5% |
Display | LCD (256 x 96 pixel) and resistive touch screen |
Case - Mounting | DIN rail |
Case - No. DIN modules | 7 |
Case - External dimensions (mm) | 126 x 100 x 70 |
EW800B
DTM (Distributed External CTs Meter) with external CTs for current measurements, equipped with integrated touch LCD display and available with
- integrated I/O module with 2digital inputs and 2 digital outputs
- serial communication interface RS485
- radio communication interface RF868 MHZ
EW800B DTM | |
---|---|
Connections | Single-phase Two-phase Three-phase with neutral Three-phase without neutral |
Measuring inputs - Current Channels | with external Current Transformers |
Measuring inputs - Voltage Channels | Direct (max rated voltage phase-neutral 230Vac) or with external Voltage Transformer (rated secondary voltage 100-115Vac, for LV or MV application) |
Power supply | 100÷230Vac |
Communication | RS485 ModBus (in all EW800… models) Radio RF868 MHz (only in EW800…200 models) Ethernet (only in EW800…300 models) |
Digital Isolated Input/Output | Voltage (phase-neutral and phase-phase) Current (phase values and neutral value) Imported Active Energy (phase values and total value) Exported Active Energy (phase values and total value) Imported Active Power (phase values and total value) Exported Active Power (phase values and total value) Reactive Power with sign (phase values and total value) Apparent Power (phase values and total value) Power Factor (phase values and total value) Frequency |
Harmonic analysis | THD (in voltage / current signal) Harmonics 1st ...51st (in voltage / current signal) |
Accuracy - Active Energy (according to IED 62053-21) | Class 1 |
Accuracy - Reactive Energy (according to IED 62053-23) | Class 2 |
Accuracy - Current and Voltage | ≤ 0,5% |
Display | LCD (256 x 96 pixel) and resistive touch screen |
Case - Mounting | DIN rail |
Case - No. DIN modules | 5 |
Case - External dimensions (mm) | 90 x 96 x 70 |
EW800C
DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements, equipped with integrated touch LCD display and available with
- integrated I/O module with 2digital inputs and 2 digital outputs
- serial communication interface RS485
- radio communication interface RF868 MHZ
EW800C DRM | |
---|---|
Connections | Single-phase Two-phase Three-phase with neutral Three-phase without neutral |
Measuring inputs - Current Channels | with external Rogowski coils |
Measuring inputs - Voltage Channels | Direct (max rated voltage phase-neutral 230Vac) or with external Voltage Transformer (rated secondary voltage 100-115Vac, for LV or MV application) |
Power supply | 100÷230Vac |
Communication | RS485 ModBus (in all EW800… models) Radio RF868 MHz (only in EW800…200 models) Ethernet (only in EW800…300 models) |
Digital Isolated Input/Output | 2 I/O module option (configurable by Data Manager) |
Measures | Voltage (phase-neutral and phase-phase) Current (phase values and neutral value) Imported Active Energy (phase values and total value) Exported Active Energy (phase values and total value) Imported Active Power (phase values and total value) Exported Active Power (phase values and total value) Reactive Power with sign (phase values and total value) Apparent Power (phase values and total value) Power Factor (phase values and total value) Frequency |
Harmonic analysis | THD (in voltage / current signal) Harmonics 1st ...51st (in voltage / current signal) |
Accuracy - Active Energy (according to IED 62053-21) | Class 1 |
Accuracy - Reactive Energy (according to IED 62053-23) | Class 2 |
Accuracy - Current and Voltage | ≤ 0,5% |
Display | LCD (256 x 96 pixel) and resistive touch screen |
Casec -Mounting | DIN rail |
Case - No. DIN modules | 5 |
Case - External dimensions (mm) | 90 x 96 x 70 |
ORDER CODES
CODES | DESCRIPTION |
---|---|
EW800A | |
EW800A3A100 | DEM (Distributed Embedded Meter) with internal shunts for current measurements up to 64A - integrated touch LCD display - serial communication interface RS485 |
EW800A3A122 | DEM (Distributed Embedded Meter) with internal shunts for current measurements up to 64A - integrated I/O module with 2 digital inputs and 2 digital outputs - integrated touch LCD display - serial communication interface RS485 |
EW800A3A200 | DEM (Distributed Embedded Meter) with internal shunts for current measurements up to 64A - integrated touch LCD display - radio communication interface RF868 MHZ |
EW800A3A222 | DEM (Distributed Embedded Meter) with internal shunts for current measurements up to 64A - integrated I/O module with 2 digital inputs and 2 digital outputs - integrated touch LCD display - radio communication interface RF868 MHZ |
EW800B | |
EW800B3A100 | DTM (Network External TA Meter) with external TA for current measurements - integrated touch LCD display - serial communication interface RS485 |
EW800B3A122 | DTM (Distributed External TA Meter) with external TA for current measurements - integrated I/O module with 2 digital inputs and 2 digital outputs - integrated touch LCD display - serial communication interface RS485 |
EW800B3A200 | DTM (Distributed External TA Meter) with external TA for current measurements - integrated touch LCD display - radio communication interface RF868 MHZ |
EW800B3A222 | DTM (Distributed External TA Meter) with external TA for current measurements - integrated I/O module with 2 digital inputs and 2 digital outputs - integrated touch LCD display - radio communication interface RF868 MHZ |
EW800B3A300 | DTM (Distributed External TA Meter) with external TA for current measurements - integrated touch LCD display - Modbus TCP/IP LAN interface |
EW800B3A322 | DTM (Distributed External TA Meter) with external TA for current measurements - integrated I/O module with 2 digital inputs and 2 digital outputs - integrated touch LCD display - Modbus TCP/IP LAN interface |
EW800C | |
EW800C3A100 | DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements - integrated touch LCD display - serial communication interface RS485 |
EW800C3A122 | DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements - integrated I/O module with 2 digital inputs and 2 digital outputs - integrated touch LCD display - serial communication interface RS485 |
EW800C3A200 | DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements - integrated touch LCD display - radio communication interface RF868 MHZ |
EW800C3A222 | DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements - integrated I/O module with 2 digital inputs and 2 digital outputs - integrated touch LCD display - radio communication interface RF868 MHZ |
EW800C3A300 | DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements - integrated touch LCD display - Modbus TCP/IP LAN interface |
EW800C3A322 | DRM (Distributed External Rogowski Meter) with external Rogowski coils for current measurements - integrated I/O module with 2 digital inputs and 2 digital outputs - integrated touch LCD display - Modbus TCP/IP LAN interface |