ESCo Kit

All it is necessary to check the energy efficiency of the plant.

 

Keeping under control the energy efficiency of a plant is a necessity and ESCo KIT of ESA Automation allows this without any problem.

Designed to simplify the supply management and installation of meters of electrical consumption, the ESCo kit is available in 2 versions: a Base Measure Switchboard and an Extension Switchboard.

BASE MEASURE SWTICHBOARD

  • 1 Esaware Data Manager EW900 with preinstalled EnergyAware software based on HTML5 technology for the acquisition, management, visualization and sharing of consumption data;
  • 2 energy meters, either DTM EW800B with external CTs or DRM EW900 with external Rogowski coils
  • All the needed components for operation and for the EN 61439-2 certification of the switchboard.
  • Options: EW800 with RF868 radio interface for wireless installation and EW900 with 3G interface for remote communication.

.

EXTENSION SWITCHBOARD

  • 3 DTM EW800B with external CTs or 3 DRM EW900 with external Rogowski coils
  • All the needed components for operation and for the EN 61439-2 certification of the switchboard.
  • Options: EW800 with RF868 radio interface for wireless installation

 

 

ESCo kit is easy to install: just connect the switchboards to the 3-phase power supply, the EW900 Data Manager to the LAN and then connect the external CTs or Rogowski coils to the measures you want to monitor. For the extension switchboard please connect the serial interface cables to the Data Manager (not needed with the RF868 radio option).

In a few steps you can count on an energetic monitoring system which is accurate and easy to us

Base Measure Switchboard

Download PDF

Base Measure SwitchboardEW8BX2x0xxx
Number of EW9001
Number of EW800x2
Voltage circuit protectionThrough fuses
I/O terminal blocks for EW9003x input, 3 x output
StructureWall mount box with transparent door
TypeBOCCHIOTTI PABLO
Nominal working voltage400 Vac
Auxiliary circuitry nominal voltage100÷230Vac (L-N) for EW800
230Vac/24Vdc (L-N) internal for EW900
Nominal frequency50 Hz
Overtemperature< 25 °C
Conditional short-circuit resistance6 kA
Measures for protection against direct contactBy means of enclosure
Measures for protection against indirect contactBy means of Class II components
Degree of protectionIP 40
Installation requirementsWall mount
Dimensions (h x w x d)450 x 408 x 135 mm
MaterialIsolating
ColorWhite RAL 9001

Extension Switchboard

Download PDF

Extension SwitchboardEW8BX3x0xxx
Number of EW9000
Number of EW800x3
Voltage circuit protectionThrough fuses
StructureWall mount box with transparent door
TypeBOCCHIOTTI PABLO
Nominal working voltage400 Vac
Auxiliary circuitry nominal voltage100÷230Vac (L-N) for EW800
Nominal frequency50 Hz
Overtemperature< 25 °C
Conditional short-circuit resistance6 kA
Measures for protection against direct contactBy means of enclosure
Measures for protection against indirect contactBy means of Class II components
Degree of protectionIP 40
Installation requirementsWall mount
Dimensions (h x w x d)400x300x113 mm
MaterialIsolating
ColorWhite RAL 9001

ORDER CODES

Download PDF

CODESDESCRIPTION
EW8BX2A0A33Electrical switchboard prepared and configured with: 1 DataManager (1 LAN, 1 RS485 , 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DTM base (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX2D0A33Electrical switchboard prepared and configured with: 1 DataManager (1 LAN, 1 RS485 , 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DRM base (energy meters with external Rogowski coil), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX2A0D33Electrical switchboard prepared and configured with: 1 DataManager (3 LANs, 1 RS485, 1 RF868, 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DTM base (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX2D0D33Electrical switchboard prepared and configured with: 1 DataManager (3 LANs, 1 RS485, 1 RF868, 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DRM base (energy meters with external Rogowski coil), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX2A0B33Electrical switchboard prepared and configured with: 1 DataManager (1 3G interface, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DTM base (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX2D0B33Electrical switchboard prepared and configured with: 1 DataManager (1 3G interface, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DRM base (energy meters with external Rogowski coil), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX2A0C33Electrical switchboard prepared and configured with: 1 DataManager (1 WiFi, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DTM base (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX3A0000Electrical switchboard prepared and configured with: 3 DTM base (energy meters with external TA), 3PN fuse switch disconnector
EW8BX3D0000Electrical switchboard prepared and configured with: 3 DRM base (energy meters with external Rogowski coil), 3PN fuse switch disconnector
EW8BX3C0000Electrical switchboard prepared and configured with: 3 DTM base (energy meters with external TA and RF868), 3PN fuse switch disconnector
EW8BX3E0000Electrical switchboard prepared and configured with: 3 DRM base (energy meters with external Rogowski and RF868), 3PN fuse switch disconnector
EW8BX3F0000Electrical switchboard prepared and configured with: 1 DTM (energy meters with external CTs and RF868), 2 DTM (energy meters with external CTs and RS485), 3PN fuse switch disconnector
EW8BX2B0A33Electrical switchboard prepared and configured with: 1 DataManager (1 LAN, 1 RS485 , 1 USB, 3 I/Os) with preinstalled EnergyAware basic software, 2 DTM with 2 I/Os (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX2B0B33Electrical switchboard prepared and configured with: 1 DataManager (1 3G interface, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DTM with 2 I/Os (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX2B0C33Electrical switchboard prepared and configured with: 1 DataManager (1 WiFi, 1 LAN, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DTM with 2 I/Os (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX2D0E33Electrical switchboard prepared and configured with: 1 DataManager (1 WiFi, 3G, 3 LANs, 1 RS485 , 1 USB, 3I/Os) with preinstalled EnergyAware basic software, 2 DRM with 2 I/Os (energy meters with external TA), power supply, 3PN fuse switch disconnector, terminal blocks for DataManager I/Os
EW8BX3B0000Electrical switchboard prepared and configured with: 3 DTM with 2 I/Os (energy meters with external TA), 3PN fuse switch disconnector