SwitchHIDRA Switch Industriale

ESA fornisce un range di switch con case industriale, integrazione dei protocolli per la ridondanza, funzionalità per la sicurezza e programmazione semplificata.
Il portafoglio ESA include switch unmanaged, managed a livello Layer2 e Layer 3, PoE (Power Over Ethernet), con protezione IP67 waterproof pensati per ambienti outdoor oppure critici.
  • Porte 10/100/1000 RJ45 e porte 100/1000 BASE-X SFP
  • Porte Power over Ethernet con alimentazione 24V DC (ESNET08UG8P00V). Non serve un alimentatore specifico.
  • Circuito per la doppia alimentazione ridondata
  • Protezione contro la inversione della polarità
  • Previsto per fissaggio a guida DIN, case in metallo
  • Range esteso di temperature da -40°C a 70°C
  • IEEE 802.3/802.3u/802.3x
  • Gestione software a livello Layer2 e Layer3
  • Ridondanza tramite l’utilizzo dei protocolli ITU-T G.8032 ERPS ring, RSTP, STP, MRP (client) compatible ring
  • Certificazioni CE, UL, NEMA, Atex zona-2, IP67
  • Gestione della segmentazione tramite LAN virtual
  • Modbus, Profinet e supporto Ethernet Ip
  • Conforme allo standard IEC62443

Unmanaged

Download pdf

HIDRA05U000000XHIDRA05UG50000AHIDRA08U000000X
Ethernet
ConnectorRJ45RJ45RJ45
Ports558
Transmission rate10/100 Mbps10/100/1000 Mbps10/100 Mbps
PoE supportNONONO
PoE voltage boosterNONONO
StandardsIEEE802.3, 802.3u, 802.3xIEEE802.3, 802.3u, 802.3x, 80.3zIEEE802.3, 802.3u, 802.3ab
Flow controlIEEE 802.3x for Flow Control, back pressure flow control IEEE 802.1q/p for VLAN Tagging and Class of Service IEEE 802.3az for Energy Efficient EthernetIEEE 802.3x for Flow Control, back pressure flow control IEEE 802.1q/p for VLAN Tagging and Class of Service IEEE 802.3az for Energy Efficient EthernetIEEE802.3X flow control, back-pressure flow control
Jumbo frame Size9216 byte10K Bytes9216 byte
Auto MDI/MDI-XYesYesYes
Power
Input voltage12 - 48 VDC12 - 48 VDC9-48 VDC
Power Consumption4.0 Watts Max4.0 Watts Max4.05 Watts
ConnectorLockable 5-pin terminal blocksLockable 5-pin terminal blocks5.08mm 5 pin Terminal Block
RedoundancyYESYESYES
Reverse Polarity Protection YESYESYES
Physical characteristics
HousingSPCC BlackSPCC BlackAlluminium
Protection levelIP30IP30IP30
InstallationDIN RailDIN RailDIN Rail
Dimension (WxHxD)Slim type, 23mm x 94mm x 72mmSlim type, 23mm x 94mm x 72mm45.2 x 90 x 78 mm
Weight420g420g255g
Led indicatorsPWR1, PWR2, Alarm, ALM, LANPWR1, PWR2, Alarm, ALM, LANPWR1, PWR2
Enviromental
Operating Temperature-40 to 70°C-40 to 70°C-10°C~70°C
Storage Temperature-40 to 85°C-40 to 85°C-40°C~85°C
Ambient Relative Humidity5 to 95%, 55°C (non-condensing)5 to 95%, 55°C (non-condensing)5 to 95%, 55°C (non-condensing)
Certifications
SafetyUL/IEC 62368-1, UL/IEC(CB) 60950-1UL/IEC(CB) 61010-2-201UL60950-1 2nd Ed. / CSA C22.2 No.60950-1-07 2nd Ed. / CB (IEC62368-1 / IEC62368-1)
FCC (EMI)FCC Part 15, Subpart B, Class AFCC Part 15, Subpart B, Class AFCC Part 15, Subpart B, Class A
CE (EMI)EN 55032:2013
EN 61000-3-2: 2014, Class A
EN 61000-3-3: 2013
EN 61000-6-4: 2007 + A1: 2011
EN 55032:2015/AC:2016 Class A
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 61000-6-4: 2007 + A1: 2011
European Standard EN55032:2012+AC:2013 Class A.
EN61000-3-2:2014, EN 61000-3-3:2013
CE (EMS)EN 55024: 2010
EN 61000-6-2:2005 + AC: 2005
IEC 61000-4-2: 2008
IEC 61000-4-3: 2010
IEC 61000-4-4: 2012
IEC 61000-4-5: 2014
IEC 61000-4-6: 2013
IEC 61000-4-8: 2009
IEC 61000-4-11: 2005
EN 55024: 2010
EN 61000-6-2:2005 + AC: 2005
IEC 61000-4-2: 2008
IEC 61000-4-3: 2010
IEC 61000-4-4: 2012
IEC 61000-4-5: 2014
IEC 61000-4-6: 2013
IEC 61000-4-8: 2009
IEC 61000-4-11: 2005
EN55024:2010(IEC 61000-4-2:2008)
IEC61000-4-3:2006/A1:2007/A2:2010, IEC 61000-4-4:2012
IEC 61000-4-5:2014, IEC 61000-4-6:2013
IEC 61000-4-8 :2009, IEC 61000-4-11:2004
ATEXNONONO
Rail TrafficNONONO
Testing report
ShockIEC 60068-2-27MIL-STD-810F Method 516.5IEC 60068-2-27
DropIEC 60068-2-32MIL-STD-810F Method 516.5IEC 60068-2-32(ISTA Test Procedure 2A)
VibrationIEC 60068-2-6MIL-STD-810F Method 514.5 C-1 & C-2IEC 60068-2-64
RoHSYESYESYES
MTBF20 years20 years30 years

HIDRA08UG80000XHIDRA08UG8P800VHIDRA05UG50000XHIDRA05UG500007
Ethernet
ConnectorRJ45RJ45RJ45M12 connector
(A or X coding)
Ports8855
Transmission rate10/100/1000 Mbps10/100/1000 Mbps10/100/1000 Mbps10/100/1000 Mbps
PoE supportNOYES (8)NONO
PoE voltage boosterNOYes (Max support 120W)NONO
StandardsIEEE802.3, 802.3u, 802.3abIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE802.3xIEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASE-FX
IEEE 802.3ab for 1000BASE-T
IEEE 802.3z for 1000BASE-X
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.3x Flow Control
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3ab for 1000BaseT
Flow controlIEEE802.3X flow control, back-pressure flow controlIEEE 802.3x for Flow Control, back pressure flow control
IEEE 802.3af/at for Power-over-Ethernet
IEEE 802.3az Energy Efficient Ethernet
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for CoS
IEEE802.3X flow control, back-pressure flow controlIEEE 802.3x for Flow Control,
Back pressure and pause frame
based flow control schemes
Jumbo frame Size9217 byte10K Bytes10K bytes10k bytes
Auto MDI/MDI-XYesYesYesYes
Power
Input voltage9-48 VDC12~57 VDC12-52 VDC12-48 VDC
Power Consumption4.05 Watts12~23VDC, max total 60W
24~57VDC, max total 120W
6 Watts5W
Connector5.08mm 5 pin Terminal BlockTerminal blockTerminal block5-Pin A-Code
Male M12
RedoundancyYESNONONO
Reverse Polarity Protection YESYESYESYES
Physical characteristics
HousingAlluminiumMetalSECCAluminum Housing
Protection levelIP30IP30IP30IP67 protection according to EN 60529
InstallationDIN RailDIN RailDIN RailWall mount
Dimension (WxHxD)45.2 x 90 x 78 mm54 x 145 x 113 mm32 x 90 x 110 mm105.7 x 196 x 48.3 mm
Weight255g700g420g650 g
Led indicatorsPWR1, PWR2P1, P2, Fault, SFP1-2, PoE LEDPWR1, PWR2, Alarm, RJ45 Act/LinkPWR1, PWR2, LAN1,
LAN2, LAN3, LAN4, LAN5
Enviromental
Operating Temperature-10°C~70°C-40°C~70°C-40°C~70°C-40°C~75°C
Storage Temperature-40°C~85°C-40°C~85°C-40°C~85°C-40°C~85°C
Ambient Relative Humidity5 to 95%, 55°C (non-condensing)5 to 95%, 55°C (non-condensing)5%~95%, 55°C (Non-condensing)5%~95%, 55°C (Non-condensing)
SafetyUL60950-1 2nd Ed. / CSA C22.2 No.60950-1-07 2nd Ed. / CB (IEC62368-1 / IEC62368-1)UL62368-1:2014(2nd Ed.)
CB/IEC60950-1:2005(2nd Ed.)
CB/IEC62368-1:2014(2nd Ed.)
UL 61010-2-201, UL C1D2EN 60950-1:2006
UL/IEC(CB) 61010-2-201
FCC (EMI)FCC Part 15, Subpart B, Class AFCC Part 15, Subpart B, Class ANOFCC Part 15 Subpart B
Class A
CE (EMI)European Standard EN55032:2012+AC:2013 Class A.
EN61000-3-2:2014, EN 61000-3-3:2014
EN 55032:2015 +AC:2016 Class A
EN 61000-3-2: 2014, Class A
EN 61000-3-3: 2013
EN 61000-6-4: 2007+ A1: 2001
EN 55024: 2010+ A1:2015
EN 61000-6-2:2005+ AC : 2005
EN 55032
EN 61000-6-4
EN 55024
EN 61000-6-2
EN 55032
EN 55024
EN 61000-3-3
EN 61000-6-2
EN 61000-6-4
CE (EMS)EN55024:2010(IEC 61000-4-2:2008)
IEC61000-4-3:2006/A1:2007/A2:2010, IEC 61000-4-4:2012
IEC 61000-4-5:2014, IEC 61000-4-6:2013
IEC 61000-4-8 :2009, IEC 61000-4-11:2005
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
ATEXNONOATEX Zone 2NO
Rail TrafficNONOEN50155 / EN50121-4NO
Testing report
ShockIEC 60068-2-27MIL-STD-810F
Method 516.5
MIL-STD-810F
Method 516.5
MIL-STD-810G
Method 516.5
DropIEC 60068-2-32(ISTA Test Procedure 2A)MIL-STD-810F
Method 516.5
MIL-STD-810F
Method 516.5
MIL-STD-810F Method 516.5
VibrationIEC 60068-2-64MIL-STD-810F
Method 514.5 C-1 & C-2
MIL-STD-810F
Method 514.5 C-1 & C-2
MIL-STD-810F Method 514.5
C-1 & C-2
RoHSYESYESYESYES
MTBF30 years20 years20 years20 years

HIDRA16UG20000X
Ethernet
ConnectorRJ45
Ports16
Transmission rate2 x 10/100 Mbps
14 x 10/100/1000 Mbps
PoE supportNO
PoE voltage boosterNO
StandardsIEEE802.3, 802.3u, 802.3ab
Flow controlIEEE802.3X flow control, back-pressure flow control
IEEE802.1p packet priorization (for profinet CC-A)
Jumbo frame Size9216 byte
Auto MDI/MDI-XYes
Power
Input voltage12~48 VDC
Power Consumption7.4 Watts
ConnectorTerminal block
RedoundancyYES
Reverse Polarity ProtectionYES
Physical characteristics
HousingAlluminium
Protection levelIP30
InstallationDIN Rail
Dimension (WxHxD)54 mm x 113mm x 145mm
Weight700g
Led indicatorsPWR1, PWR2
Enviromental
Operating Temperature-10°C~60°C
Storage Temperature-20°C~70°C
Ambient Relative Humidity5 to 95%, 55°C (non-condensing)
Certifications
SafetyEN60950-1:2006,
UL/IEC(CB) 60950/62368
FCC (EMI)FCC Part 15, Subpart B, Class A
CE (EMI)FCC Part 15, Subpart B, Class A
EN 55032
EN 55024
EN 61000-6-4
EN 61000-6-2
CE (EMS)IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
ATEXNO
Rail TrafficNO
Testing report
ShockIEC 60068-2-27
DropIEC 60068-2-32
VibrationIEC 60068-2-6
RoHSYES
MTBF20 years

Managed

Download pdf

HIDRA08MG80000XHIDRA08MG8P800XHIDRA08MG8P4F4XHIDRA08MG800007
Interface
Connector8888
Ethernet Ports8 x RJ458 x RJ454 x RJ458 x M12
SFP PortsNONO4 x SFPNO
Transmission rate10/100/1000BASE-T(X)
auto negotiation speed
10/100/1000BASE-T(X)
auto negotiation speed
10/100/1000BASE-T(X)
auto negotiation speed
10/100/1000BASE-T(X)
auto negotiation speed
Fiber PortsNONO100BASE-FX / 1000BASE-X SFP slotNO
PoE supportNOYESYESNO
PoE voltage boosterNOYESYESNO
ConsoleRS232 (RJ45 connector)RS232 (RJ45 connector)RS232 (RJ45 connector)RS232 (A-coding M12 connector)
Relay Output2 relay outputs
with current carrying capacity of 2A @30VDC
2 relay outputs
with current carrying capacity of 2A @30VDC
2 relay outputs
with current carrying capacity of 2A @30VDC
2 relay outputs
with current carrying capacity of 1A @ 24 VDC
(through A-coding M12 connector)
DIP SwitchesRing ControlRing ControlRing ControlNO
Reset buttonYESYESYESNO
Technology
StandardsIEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASEFX
IEEE802.3ab for 1000BASE-T(X)
IEEE802.3z for 1000BASE-X
IEEE802.3af / 802.3at for Power-over-Ethernet
IEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASEFX
IEEE802.3ab for 1000BASE-T(X)
IEEE802.3z for 1000BASE-X
IEEE802.3af / 802.3at for Power-over-Ethernet
IEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASEFX
IEEE802.3ab for 1000BASE-T(X)
IEEE802.3z for 1000BASE-X
IEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASEFX
IEEE802.3ab for 1000BASE-T(X)
IEEE802.3z for 1000BASE-X
Flow controlIEEE802.3x for Flow Control
IEEE802.1D-2004 for Spanning Tree Protocol
IEEE802.1w for Rapid STP IEEE802.1Q for VLAN Tagging
IEEE802.1p for Class of Service IEEE8021X for Authentication
IEEE802.3ad for Port Trunk with LACP
IEEE802.3x for Flow Control
IEEE802.1D-2004 for Spanning Tree Protocol
IEEE802.1w for Rapid STP IEEE802.1Q for VLAN Tagging
IEEE802.1p for Class of Service IEEE8021X for Authentication
IEEE802.3ad for Port Trunk with LACP
IEEE802.3x for Flow Control
IEEE802.1D-2004 for Spanning Tree Protocol
IEEE802.1w for Rapid STP IEEE802.1Q for VLAN Tagging
IEEE802.1p for Class of Service IEEE8021X for Authentication
IEEE802.3ad for Port Trunk with LACP
IEEE 802.1d-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP
ProtocolsIPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/
v2c/v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Relay/Client, BootP, TFTP, NTP
Server/Client, SNTP, SMTP, SMTP(Gmail), RMON, HTTP, Syslog, MRP (Client),
LLDP, IEEE 1588 PTP V1/V2, 802.1x, EAP, RADIUS, TACACS+, Mirror port, QoS,
ACL, Serial Console, U-Ring, STP, RSTP, MSTP, Redundancy Compatible Ring,
Profinet, Modbus/TCP, UDLD, Security, Trunk,LACP, MLD, 802.1Q VLAN, Port Based VLAN,MAC-
Based VLAN, IP-Subnet-Based VLAN, Protocol-Based VLAN,
QinQ,802.1x, ARP spoof Prevention, DHCP snooping, IP source Guard, Dynamic
ARP Inspection, DHCP relay Agent
IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/
v2c/v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Relay/Client, BootP, TFTP, NTP
Server/Client, SNTP, SMTP, SMTP(Gmail), RMON, HTTP, Syslog, MRP (Client),
LLDP, IEEE 1588 PTP V1/V2, 802.1x, EAP, RADIUS, TACACS+, Mirror port, QoS,
ACL, Serial Console, U-Ring, STP, RSTP, MSTP, Redundancy Compatible Ring,
Profinet, Modbus/TCP, UDLD, Security, Trunk,LACP, MLD, 802.1Q VLAN, Port Based VLAN,MAC-
Based VLAN, IP-Subnet-Based VLAN, Protocol-Based VLAN,
QinQ,802.1x, ARP spoof Prevention, DHCP snooping, IP source Guard, Dynamic
ARP Inspection, DHCP relay Agent
IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/
v2c/v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Relay/Client, BootP, TFTP, NTP
Server/Client, SNTP, SMTP, SMTP(Gmail), RMON, HTTP, Syslog, MRP (Client),
LLDP, IEEE 1588 PTP V1/V2, 802.1x, EAP, RADIUS, TACACS+, Mirror port, QoS,
ACL, Serial Console, U-Ring, STP, RSTP, MSTP, Redundancy Compatible Ring,
Profinet, Modbus/TCP, UDLD, Security, Trunk,LACP, MLD, 802.1Q VLAN, Port Based VLAN,MAC-
Based VLAN, IP-Subnet-Based VLAN, Protocol-Based VLAN,
QinQ,802.1x, ARP spoof Prevention, DHCP snooping, IP source Guard, Dynamic
ARP Inspection, DHCP relay Agent
IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping,GARP,GMRP, GVRP, SNMPv1/v2c/
v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Server/Relay/Client, DHCP Option
66/67/82, BootP, RARP, TFTP, NTP Server/Client, SNTP, SMTP, SMTP (Gmail),
RMON, HTTP, HTTPS, Syslog, MRP (Client), LLDP, IEEE 1588 PTP V1/V2,
IEEE 1588 Hardware E2E Transparent Clock, 802.1x, EAP, RADIUS, TACACS+,
Mirror port, QoS, ACL, Serial Console, U-Ring, STP, RSTP, MSTP, Redundancy
Compatible Ring
Automation profilesProfinet CC-B v2.33 certified,
GSDML file provided
Profinet CC-B v2.33 certified,
GSDML file provided
Profinet CC-B v2.33 certified,
GSDML file provided
Modbus/TCP status registers
MIBMIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC
RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011,
RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415
MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC
RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011,
RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415
MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC
RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011,
RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415
MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC
RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011,
RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 2674
Switch Properties
Priority Queues8888
Max. Number of Available
VLANs
2562562564096
VLAN ID RangeVID 1 to 4094VID 1 to 4094VID 1 to 4094VID 1 to 4094
Static IGMP Groups256256256128
Dynamic IGMP Groups256256256256
MAC Table Size16K16K16K16k
Packet Buffer Size12 Mbit12 Mbit12 Mbit1.5Mb
Power
Input voltage9-48 VDC9-48 VDC9-48 VDC12~57 VDC
Input current3.0A @24V3.0A @24V3.0A @24V1.19A @24V
ConnectorRemovable 5-pin Terminal BlockRemovable 5-pin Terminal BlockRemovable 5-pin Terminal Block2 x S-Coding M12 connectors (4 Pin)
RedoundancyYESYESYESYES
Reverse Polarity Protection YESYESYESYES
Physical characteristics
HousingMetalMetalMetalAlluminium, IP67 protection
according to EN 60529
Protection levelIP30IP30IP30IP67
InstallationDIN-RailDIN-RailDIN-RailWall-mount
Dimension (WxHxD)60.3mm x 137.9mm x 164mm60.3mm x 137.9mm x 164mm60.3mm x 137.9mm x 164mm216mm x 232mm x 72mm
Weight1200g1200g1200g2000 g
Led indicatorsPWR1, PWR2, Alarm, Run, Ring,
Ring Master, RJ-45 Link/Speed,
PWR1, PWR2, Alarm, Run, Ring,
Ring Master, RJ-45 Link/Speed, PoE
PWR1, PWR2, Alarm, Run, Ring,
Ring Master, RJ-45 Link/Speed, PoE
PWR1, PWR2, Alarm,
Ethernet Act/Link, Ring
Enviromental
Operating Temperature20°C~70°C20°C~70°C20°C~70°C-40°C~75°C
Storage Temperature-40°C~85°C-40°C~85°C-40°C~85°C-40°C~85°C
Ambient Relative Humidity5%~95%, 55°C (Non-condensing)5%~95%, 55°C (Non-condensing)5%~95%, 55°C (Non-condensing)5%~95%, 55°C (Non-condensing)
Certifications
SafetyUL60950-1
2nd Ed. /CSA C22.2 No.60950-1-07
2nd Ed. / CB (IEC/EN62368-1 & IEC/EN60950-1)
UL60950-1
2nd Ed. /CSA C22.2 No.60950-1-07
2nd Ed. / CB (IEC/EN62368-1 & IEC/EN60950-1)
UL60950-1
2nd Ed. /CSA C22.2 No.60950-1-07
2nd Ed. / CB (IEC/EN62368-1 & IEC/EN60950-1)
EN 60950-1:2006,
UL/IEC(CB) 61010-2-201
EMCFCC Part 15, Subpart B, Class A /
EN 61000-6-4:2007+A1:2011 /
EN 61000-6-2:2005
FCC Part 15, Subpart B, Class A /
EN 61000-6-4:2007+A1:2011 /
EN 61000-6-2:2005
FCC Part 15, Subpart B, Class A /
EN 61000-6-4:2007+A1:2011 /
EN 61000-6-2:2005
FCC Part 15, Subpart B, Class A
EN 55032, EN 55024, EN 61000-3-2, EN 61000-3-3,
EN 61000-6-2, EN 61000-6-4,
Rail trafficNONONOEN50155, EN50121-4, IEC60571, EN45545-2
TestIEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
Testing report
ShockIEC 60068-2-27IEC 60068-2-27IEC 60068-2-27MIL-STD-810G Method 516.5
DropIEC 60068-2-32IEC 60068-2-32IEC 60068-2-32MIL-STD-810F Method 516.5
VibrationIEC 60068-2-64IEC 60068-2-64IEC 60068-2-64MIL-STD-810F Method 514.5 C-1 & C-2
Trafic controlNEMA TS-2NEMA TS-2NEMA TS-2NO
RoHSYESYESYESYES
MTBF11 years11 years11 years20 years

Layer 3

Download pdf

HIDRA083G80000X
Interface
Connector8
Ethernet Ports8 x RJ45
SFP PortsNO
Transmission rate10/100/1000BASE-T(X)
auto negotiation speed
Fiber PortsNO
PoE supportNO
PoE voltage boosterNO
ConsoleRS232 (RJ45 connector)
Relay Output2 relay outputs
with current carrying capacity of 1A @24VDC
DIP SwitchesRing Control and Profinet settings
Reset buttonNO
Technology
StandardsIEEE802.3 for 10BASE-T
IEEE802.3u for 100BASE-T(X) and 100BASEFX
IEEE802.3ab for 1000BASE-T(X)
IEEE802.3z for 1000BASE-X
Flow controlIEEE802.3x for Flow Control
IEEE 802.3x for Flow Control
IEEE 802.1d-2004 for Spanning Tree Protocol
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1s for Multiple Spanning Tree Protocol
IEEE 802.1q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 8021x for Authentication
IEEE 802.3ad for Port Trunk with LACP
ProtocolsIPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/v2c/
v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Server/Relay/Client, DHCP Option
66/67/82, BootP, RARP, TFTP, SMTP, SMTP (Gmail), RMON, HTTP, HTTPS,
Syslog, MRP (Client),LLDP,802.1x,EAP,RADIUS,TACACS+,Mirror port, QoS, ACL
Layer-3 ProtocolsRouting: IPv4 Unicast static routing, RIP v1/v2, OSPFv2,
Multicast: IGMPv1/v2/v3, DVMRP, PIM-DM, PIM-SM, PIM-SSM
Routing Redundancy: VRRP (Virtual Router Redundancy Protocol)
RedoundancyITU-T G.8032 ERPS Ring, STP, RSTP, MSTP, Compatible Ring/Chain, U-Ring
Time Synchronization
Network Synchronization
Precision Network
Synchronization
Time Synchronization
NTP Server/Client, SNTP
IEEE1588v1 OC/BC (Software)
IEEE1588v2 E2E TC (Hardware) - ns acc.
IEEE1588v2 OC/BC (Software)
Automation profilesModbus/TCP status registers
SNMP MIBMIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC
RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011,
RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863,
RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 2674
Switch Properties
Priority Queues8
VLAN Table4096
MAC based VLAN512
VLAN ID RangeVID 1 to 4094
Trunk Group4
Static IGMP Groups256
Dynamic IGMP Groups256
MAC Table Size16K
Packet Buffer Size1.5MB
Jumbo frame9216 Byte
Power
Input voltage9-57 VDC
Input current1.4A
Connector5-Pin 5.08mm Lockable Terminal Block
RedoundancyYES
Reverse Polarity Protection YES
Physical characteristics
HousingAlluminium
Protection levelIP30
InstallationDIN-Rail
Dimension (WxHxD)54mm x 113mm x 145 mm
Weight800g
Led indicatorsPWR1, PWR2, Alarm, Run, Ring,
Ring Master, RJ-45 Link/Speed
Enviromental
Operating Temperature-20°C~70°C
Storage Temperature-40°C~85°C
Ambient Relative Humidity5%~95%, 55°C (Non-condensing)
Certifications
SafetyUL 60950-1 2nd Ed. /CSA C22.2 No.60950-1-07 2nd Ed. /
EN 60950-1 / CB
EMCFCC Part 15, Subpart B, Class A
EN 55032, EN 55024, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2, EN 61000-6-4
Traffic ControlNEMA TS-2
Rail trafficEN50155 - EN50121-4
TestIEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
Testing report
ShockMIL-STD-810G Method 516.5
DropMIL-STD-810F Method 516.5
VibrationMIL-STD-810F Method 514.5 C-1 & C-2
High AltitudeCertified for altitudes up to 4,000m, according to IEC 60068-2-13
RoHS IIYES
MTBF20 years